Episode 771: Double-Tapped Neutral Wires Are a Defect for Home Inspectors

20/08/2025 12 min Episodio 771
Episode 771: Double-Tapped Neutral Wires Are a Defect for Home Inspectors

Listen "Episode 771: Double-Tapped Neutral Wires Are a Defect for Home Inspectors"

Episode Synopsis


Understanding your home’s electrical safety features protects both property and occupants. Regular professional inspections of electrical systems helps identify legacy installations that may no longer meet current safety standards. Double-lugging neutral conductors is a significant safety hazard and a major defect that can lead to loose connections, overheating, and arcing. The 2023 NEC 110.14(A) and NEC 408.41 now specifically prohibit double-lugging and mandate individual terminals for each neutral conductor. The NEC does not permit the termination of more than one neutral wire under a single screw at the neutral bus bar. 